Organic Standard Solutions Explained - And When It’s Time To Go Custom
Posted by Delta Scientific on 2026 Nov 24th

In this blog, you will learn:
- What organic standard solutions are used for
- The differences between inorganic and organic standard solutions
- When you should choose to use custom reference standards and how to specify them for your laboratory
Struggling with irregular measurements? Or are you needing support with the calibration of instruments? It’s a regular pain point for laboratory managers and research scientists that can be solved with organic standard solutions or custom standards.
Ready to learn which standard will solve your challenges? Read more now.
What Are Organic Standard Solutions Used For?
Organic standard solutions, or organic reference standards, are made from organic compounds such as carbon-based molecules, pesticides, PFAS, and pharmaceuticals with certified, known concentrations and purity.
Laboratories use organic standard solutions to support them in the calibration of instruments, helping them to confirm that a method is measuring accurately and reducing the risk of inaccuracy.
For example, calibration is a core reason why organic standard solutions are used in the lab. Typically, analytical instruments cannot directly measure concentration; instead, they measure the peak area, height, and absorbance, which correlates with concentration.
Using organic standard solutions of known concentration, a series of dilutions are prepared that bracket the expected range of real samples. Each dilution is run on the laboratory instrument, producing a signal-versus-concentration plot. Software then creates a regression line through these points. After that, unknown samples are run, and their signal is mapped back onto the curve to calculate concentration.
Other ways that organic standards can support laboratories include:
- Method validation and verification: Organic standard solutions are used to determine a blank matrix and the limit of detection and quantitation. They also help to check specificity and establish linearity, precision, and accuracy.
- Quality control: Organic standard solutions are used to ensure accuracy, including spiked recovery samples, matrix spikes, surrogate standards, and to continue calibration verification.
In short, organic standard solutions provide researchers with confidence by validating that laboratory instruments are properly calibrated, verifying methods prior to analyzing real samples, and preventing expensive errors.
So, how do inorganic standard solutions fit into the picture?
How are Inorganic Standard Solutions Different?
Inorganic standard solutions are different from their organic alternatives, as they typically contain single elements or simple ions, such as metals like lead, arsenic, and mercury. Chemically, they're usually just one element dissolved in a dilute acidic matrix such as nitric or hydrochloric acid to keep it stable in solution.
One of themain differences is that inorganic standard solutions aren’t used on instruments that measure molecules, but on those that measure atoms instead.
Compared to organic standard solutions, inorganic alternatives are typically more stable, as their elements don’t degrade and can sit at room temperature for longer.
However, there are a number of differences that we have clearly outlined in our table below:
|
Feature / Attribute |
Organic Standard Solutions |
Inorganic Standard Solutions |
|---|---|---|
|
Composition |
Molecular compounds (pesticides, PFAS, PAHs, pharmaceuticals, VOCs) |
Single elements or simple ions (metals, anions like nitrate/sulfate/chloride) |
|
Typical instrumentation |
GC-MS, LC-MS, HPLC, GC-FID |
ICP-MS, ICP-OES, AA (atomic absorption) |
|
What's measured |
Molecular structure/fragmentation pattern |
Elemental signal (atom-based) |
|
Stability |
Fragile — prone to oxidation, hydrolysis, photodegradation, volatilization |
Very stable — elements don't degrade |
|
Storage requirements |
Often needs refrigeration/freezing, amber glass, shorter shelf life |
Generally stable at room temperature, longer shelf life |
|
Matrix/solvent |
Compound-specific solvents (methanol, acetonitrile, hexane, isooctane) |
Typically a standardized dilute acid matrix (HNO₃ or HCl) |
|
Complexity of certification |
Can involve structural isomers, multi-analyte mixes, specificity challenges |
Usually a single, well-characterized element — simpler to certify |
|
Common industries/use cases |
Pesticide residues, PFAS, pharmaceuticals, cannabis testing, petrochemicals, forensic toxicology |
Drinking water metals, soil heavy metals, mining/industrial discharge, food safety metal limits |
Now that you know the key differences. But how do you choose the right standard for your method and matrix?
How to Choose the Right Reference Standard for Your Method and Matrix
There are four main questions that you need to ask yourself before deciding on the reference standard that matches your method and matrix:
- What are you trying to prove? If you are trying to confirm identity, then a pure reference standard is fine. However, if you are measuring an amount, you need to choose a standard that has a certified purity and concentration.
- Does my reference standard fit my method?
- Does my matrix mess with the results? Most people forget about this aspect, and this can cause the most errors. Your best option is to make your standard in the same blank matrix as your sample.
- Is there a required standard? If you’re following USP, EPA, ISO, check your method first and it may tell you which standard to use.
Okay, so what if there are no off-the-shelf standards that match your method and matrix? That's when you choose custom organic reference standards.
When to Choose Custom Organic Standard Solutions
If your method and matrix require organic standard solutions that are specific, then that’s when you should choose custom alternatives.
Beyond reference standard requirements, there are several key reasons you might require custom organic alternatives:
- Specific isotope-labeled variants
- Tailored salt forms, isomers, or derivatives
- Standards for impurities or degradation products
- Regulatory or method validation mandates for specialized reference materials
- Unique scale or purity specifications
- Supply chain availability or cost considerations
Our custom organic standards can be requested via forms that allow you to specify the exact required compounds, concentrations, and matrices.
Custom Organic Standard Solutions: Order Now
Increase the accuracy of your research results and support the calibration of your equipment with organic standards that match your matrix and method.
Explore our entire range of organic standard solutions suited to your research. Or if it’s custom reference standards that you’re looking for, you can get in touch with our team here and fill out your custom form.