What Are Organic Standard Solutions Used For? 

Organic standard solutions, or organic reference standards, are made from organic compounds such as carbon-based molecules, pesticides, PFAS, and pharmaceuticals with certified, known concentrations and purity.

Laboratories use organic standard solutions to support them in the calibration of instruments, helping them to confirm that a method is measuring accurately and reducing the risk of inaccuracy.

For example, calibration is a core reason why organic standard solutions are used in the lab. Typically, analytical instruments cannot directly measure concentration; instead, they measure the peak area, height, and absorbance, which correlates with concentration.

Using organic standard solutions of known concentration,  a series of dilutions are prepared that bracket the expected range of real samples. Each dilution is run on the laboratory instrument, producing a signal-versus-concentration plot. Software then creates a regression line through these points. After that, unknown samples are run, and their signal is mapped back onto the curve to calculate concentration.

Other ways that organic standards can support laboratories include:

  • Method validation and verification: Organic standard solutions are used to determine a blank matrix and the limit of detection and quantitation. They also help to check specificity and establish linearity, precision, and accuracy.
  • Quality control: Organic standard solutions are used to ensure accuracy, including spiked recovery samples, matrix spikes, surrogate standards, and to continue calibration verification.

In short, organic standard solutions provide researchers with confidence by validating that laboratory instruments are properly calibrated, verifying methods prior to analyzing real samples, and preventing expensive errors.

So, how do inorganic standard solutions fit into the picture?

How are Inorganic Standard Solutions Different? 

Inorganic standard solutions are different from their organic alternatives, as they typically contain single elements or simple ions, such as metals like lead, arsenic, and mercury. Chemically, they're usually just one element dissolved in a dilute acidic matrix such as nitric or hydrochloric acid to keep it stable in solution.

One of themain differences is that inorganic standard solutions aren’t used on instruments that measure molecules, but on those that measure atoms instead. 

Compared to organic standard solutions, inorganic alternatives are typically more stable, as their elements don’t degrade and can sit at room temperature for longer. 

However, there are a number of differences that we have clearly outlined in our table below:

Feature / Attribute

Organic Standard Solutions

Inorganic Standard Solutions

Composition

Molecular compounds (pesticides, PFAS, PAHs, pharmaceuticals, VOCs)

Single elements or simple ions (metals, anions like nitrate/sulfate/chloride)

Typical instrumentation

GC-MS, LC-MS, HPLC, GC-FID

ICP-MS, ICP-OES, AA (atomic absorption)

What's measured

Molecular structure/fragmentation pattern

Elemental signal (atom-based)

Stability

Fragile — prone to oxidation, hydrolysis, photodegradation, volatilization

Very stable — elements don't degrade

Storage requirements

Often needs refrigeration/freezing, amber glass, shorter shelf life

Generally stable at room temperature, longer shelf life

Matrix/solvent

Compound-specific solvents (methanol, acetonitrile, hexane, isooctane)

Typically a standardized dilute acid matrix (HNO₃ or HCl)

Complexity of certification

Can involve structural isomers, multi-analyte mixes, specificity challenges

Usually a single, well-characterized element — simpler to certify

Common industries/use cases

Pesticide residues, PFAS, pharmaceuticals, cannabis testing, petrochemicals, forensic toxicology

Drinking water metals, soil heavy metals, mining/industrial discharge, food safety metal limits

Now that you know the key differences. But how do you choose the right standard for your method and matrix?

How to Choose the Right Reference Standard for Your Method and Matrix

There are four main questions that you need to ask yourself before deciding on the reference standard that matches your method and matrix:

  1. What are you trying to prove? If you are trying to confirm identity, then a pure reference standard is fine. However, if you are measuring an amount, you need to choose a standard that has a certified purity and concentration.
  2. Does my reference standard fit my method?  
  3. Does my matrix mess with the results? Most people forget about this aspect, and this can cause the most errors. Your best option is to make your standard in the same blank matrix as your sample. 
  4. Is there a required standard? If you’re following USP, EPA, ISO, check your method first and it may tell you which standard to use.

Okay, so what if there are no off-the-shelf standards that match your method and matrix? That's when you choose custom organic reference standards. 

When to Choose Custom Organic Standard Solutions 

If your method and matrix require organic standard solutions that are specific, then that’s when you should choose custom alternatives. 

Beyond reference standard requirements, there are several key reasons you might require custom organic alternatives:

  • Specific isotope-labeled variants
  • Tailored salt forms, isomers, or derivatives
  • Standards for impurities or degradation products
  • Regulatory or method validation mandates for specialized reference materials
  • Unique scale or purity specifications
  • Supply chain availability or cost considerations

Our custom organic standards can be requested via forms that allow you to specify the exact required compounds, concentrations, and matrices. 

Custom Organic Standard Solutions: Order Now

Increase the accuracy of your research results and support the calibration of your equipment with organic standards that match your matrix and method.

Explore our entire range of organic standard solutions suited to your research. Or if it’s custom reference standards that you’re looking for, you can get in touch with our team here and fill out your custom form.

Why Purchase

Through OECM?

As part of our OECM agreement, Delta Scientific supports a wide range of laboratory and science needs, including:

 

- Streamlined Procurement – Simplify your purchasing process with direct access to our products via OECM.

 

- Competitive Pricing – Enjoy cost savings through pre-negotiated agreements.

 

- Trusted Expertise – Work with a supplier that understands the needs of the education sector.

 

- Extensive Product Range – From everyday laboratory essentials to specialist equipment.

How to Buy

As part of our OECM agreement, Delta Scientific supports a wide range of laboratory and science needs, including:

 

1. Visit the OECM Laboratory and Science Supplies Marketplace.

 

2. Search for Delta Scientific within the supplier list.

 

3. Add Delta Scientific as a preferred vendor for your facility.

 

4. Start purchasing directly through OECM at preferential rates

Request a Copy of

Our OECM Contract

To access a copy of our OECM contract or learn more about how we

support educational facilities, please complete the form below.

A member of our team will follow up with the relevant

documentation and next steps.

Need Help?

If you’d like guidance on getting set up or want to discuss your institution’s specific needs, we’re here to help.

Call us: 905-629-4545. Contact us: info@delta-sci.com